PERFORMANCE AT A GLANCE OF THERMAL AND HYDEL POWER STATIONS OF HPGCL SINCE 2009-10 to 2014-15 |
||||||
Description |
2009-10 |
2010-11 |
2011-12 |
2012-13 |
2013-14 |
2014-15 |
PTPS-1 (Units I-IV) |
|
|
|
|
|
|
Generation (MU) |
2681.40 |
2093.69 |
2506.14 |
1993.39 |
385.98 |
477.606 |
PLF(%) |
68.38 |
53.37 |
63.71 |
50.82 |
9.84 |
12.18 |
Aux. Consumption (%) |
11.40 |
12.00 |
12.54 |
12.62 |
14.46 |
14.88 |
Coal Consumption (gm/kwh) |
840 |
902 |
909 |
864 |
828 |
858 |
Oil Consumption (ml/kwh) |
2.44 |
5.8 |
5.56 |
5.81 |
4.13 |
6.39 |
Station Heat Rate (Kcal/kwh) |
3225 |
3349 |
3211 |
3126 |
3021 |
3057 |
PTPS-2 (Units V-VIII) |
|
|
|
|
|
|
Generation (MU) |
7525.43 |
7179.60 |
7230.20 |
6937.90 |
4811.89 |
3926.08 |
PLF (%) |
93.38 |
89.09 |
89.47 |
86.09 |
59.71 |
48.72 |
Aux. Consumption (%) |
9.13 |
9.66 |
9.80 |
9.87 |
10.04 |
10.46 |
Coal Consumption (gm/kwh) |
672 |
732 |
767 |
711 |
697 |
698 |
Oil Consumption (ml/kwh) |
1.05 |
2.68 |
1.25 |
0.84 |
0.82 |
0.95 |
Station Heat Rate (Kcal/kwh) |
2561 |
2679 |
2662 |
2538 |
2519 |
2497 |
PANIPAT THERMAL POWER STATION, PANIPAT (1367.8 MW) |
|
|
|
|
|
|
Generation (MU) |
10206.827 |
9273.29 |
9736.34 |
8931.29 |
5197.87 |
4403.68 |
PLF (%) |
85.19 |
77.39 |
81.04 |
74.54 |
43.38 |
36.75 |
Aux. Consumption (%) |
9.73 |
10.19 |
10.5 |
10.48 |
10.37 |
10.94 |
Coal Consumption (gm/kwh) |
716 |
770 |
804 |
745 |
707 |
715 |
Oil Consumption (ml/kwh) |
1.41 |
3.38 |
2.36 |
1.95 |
1.07 |
1.54 |
Station Heat Rate (Kcal/kwh) |
2736 |
2831 |
2804 |
2668 |
2551 |
2559 |
Gross Calorific Value (Kcal/kg) |
3801 |
3636 |
3463 |
3557 |
3595 |
3560 |
FARIDABAD THERMAL POWER STATION (165 MW) |
|
|
|
|
|
|
Generation (MU) |
383.769 |
- |
- |
- |
- |
- |
Plant Load Factor (%) |
55.70 |
- |
- |
- |
- |
- |
Aux. Consumption (%) |
16.07 |
- |
- |
- |
- |
- |
Coal Consumption (gm/kwh) |
1167 |
- |
- |
- |
- |
- |
Oil Consumption (ml/kwh) |
6.01 |
- |
- |
- |
- |
- |
Station Heat Rate (Kcal/kwh) |
4604 |
- |
- |
- |
- |
- |
Gross Calorific Value (Kcal/kg) |
3894 |
- |
- |
- |
- |
- |
DCRTPP, YAMUNANAGAR (600 MW) |
|
|
|
|
|
|
Generation (MU) |
4275.912 |
3881.18 |
3238.71 |
963.31 |
3472.36 |
3515.54 |
Plant Load Factor (%) |
81.35 |
73.85 |
61.45 |
18.33 |
66.06 |
66.89 |
Aux. Consumption (%) |
9.29 |
9.73 |
9.34 |
10.46 |
9.05 |
8.83 |
Coal Consumption (gm/kwh) |
641 |
691 |
671 |
648 |
655 |
645 |
Oil Consumption (ml/kwh) |
1.70 |
2.35 |
2.24 |
2.71 |
0.82 |
0.75 |
Station Heat Rate (Kcal/kwh) |
2387 |
2479 |
2414 |
2395 |
2386 |
2336 |
Gross Calorific Value (Kcal/kg) |
3725 |
3589 |
3600 |
3657 |
3633 |
3613 |
RGTPP, HISAR (1200 MW) |
|
|||||
Generation (MU) |
- |
- |
5558.26 |
4992.92 |
4381.96 |
5720.72 |
Plant Load Factor (%) |
- |
- |
52.73 |
47.5 |
41.69 |
54.42 |
Aux. Consumption (%) |
- |
- |
6.37 |
5.93 |
5.83 |
5.95 |
Coal Consumption (gm/kwh) |
- |
- |
756 |
745 |
741 |
710.98 |
Oil Consumption (ml/kwh) |
- |
- |
2.795 |
1.287 |
0.604 |
0.39 |
Station Heat Rate (Kcal/kwh) |
- |
- |
2638 |
2543 |
2373 |
2390 |
Gross Calorific Value (Kcal/kg) |
- |
- |
3450 |
3399 |
3192 |
3355.99 |
HPGCL THERMAL |
|
|
|
|
|
|
Generation (MU) |
14866.508 |
13161.82 |
18533.32 |
14887.52 |
13052.19 |
13639.94 |
Plant Load Factor (%) |
82.93 |
76.28 |
66.60 |
53.65 |
47.04 |
49.15 |
Aux. Consumption (%) |
9.77 |
10.06 |
9.06 |
8.96 |
8.49 |
8.30 |
Coal Consumption (gm/kwh) |
706 |
747 |
766 |
739 |
705 |
695 |
Oil Consumption (ml/kwh) |
1.61 |
3.08 |
2.47 |
1.78 |
0.85 |
0.85 |
Station Heat Rate(Kcal/kwh) |
2684 |
2728 |
2686 |
2608 |
2447 |
2431 |
WYC HYDEL (62.4 MW) |
|
|
|
|
|
|
Generation (MU) |
235.419 |
272.70 |
285.30 |
247.20 |
204.25 |
178.08 |
HPGCL (Thermal+Hydel = 2140.2 MW) |
|
|
|
|
|
|
Generation (MU) |
15101.9 |
13434.52 |
18818.61 |
15134.72 |
13256.45 |
13818.02 |